APC APDU10450SW NetShelter Rack PDU Advanced, Switched, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A

查詢價錢

NetShelter Rack PDU Advanced, Switched, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A。規格以原廠資料為準。

此型號可由傑成系統有限公司上門安裝(保安牌照 1507)。身份為安裝商及經銷商。安裝見閉路電視安裝;保養見保養;其他公司系統維修見維修。

  • 持牌安裝(保安公司牌照 1507)
  • 原廠行貨,原廠保用
  • 全港免費上門勘察
貨號: APDU10450SW 分類: ,

描述

APDU10450SW

NetShelter Rack PDU Advanced, Switched, 3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A

APDU10450SW 屬APC伺服器機櫃及機房設備產品。傑成系統有限公司(香港防盜)為APC產品安裝商及經銷商,可提供供應、安裝、調試、保養及維修,可配合網絡佈線、UPS 及機房環境監測一併規劃。方案可參考Server Room 架設及維修。規格以原廠資料為準。

產品說明

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center.

規格

主要規格

Product or component type PDU
Main Input Voltage 415 V 3 phases
Input current limits 60 A
Network frequency 50/60 Hz
Main Output Voltage 240 V
Input Connection Type IEC 60309 60 A 3P + N + PE
Number of power socket outlets 21 C13/C15/C19/C21 ; 21C13/C15
Load capacity 34600 VA
[In] rated current 48 A
permissible voltage 200…240 V; 346…415 V
Max current draw 48 A
PDU type Switched
Protection type Circuit breaker
Number of rack unit 0U
Cable length 1.8 m

補充規格

Mounting location Side
Mounting mode Rack-mounted
Mounting position Vertical
Communication port protocol 1000BASE-T; 10/100BASE-T
Height 1826 mm
Width 56 mm
Depth 75 mm
Net weight 12.4 kg