APC APDU10150SM NetShelter Rack PDU Advanced, Switched Metered Outlet, 7.4kW, 1Phase

查詢價錢

NetShelter Rack PDU Advanced, Switched Metered Outlet, 7.4kW, 1Phase。規格以原廠資料為準。

此型號可由傑成系統有限公司上門安裝(保安牌照 1507)。身份為安裝商及經銷商。安裝見閉路電視安裝;保養見保養;其他公司系統維修見維修。

  • 持牌安裝(保安公司牌照 1507)
  • 原廠行貨,原廠保用
  • 全港免費上門勘察
貨號: APDU10150SM 分類: ,

描述

APDU10150SM

NetShelter Rack PDU Advanced, Switched Metered Outlet, 7.4kW, 1Phase

APDU10150SM 屬APC伺服器機櫃及機房設備產品。傑成系統有限公司(香港防盜)為APC產品安裝商及經銷商,可提供供應、安裝、調試、保養及維修,可配合網絡佈線、UPS 及機房環境監測一併規劃。方案可參考Server Room 架設及維修。規格以原廠資料為準。

產品說明

APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 40 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded by breaker to simplify deployment. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensure

規格

主要規格

Product or component type PDU
Main Input Voltage 230 V 1 phase
Input current limits 32 A
Network frequency 50/60 Hz
Main Output Voltage 230 V
Input Connection Type IEC 60309 32 A 2P + PE
Number of power socket outlets 20 C13/C15/C19/C21 ; 20C13/C15
Load capacity 7400 VA
[In] rated current 32 A
permissible voltage 200…240 V
Max current draw 32 A
PDU type Switched metered outlet
Protection type Circuit breaker
Number of rack unit 0U
Cable length 3.0 m

補充規格

Mounting location Side
Mounting mode Rack-mounted
Mounting position Vertical
Communication port protocol 1000BASE-T; 10/100BASE-T
Height 1490 mm
Width 56 mm
Depth 75 mm
Net weight 7.5 kg