描述
APDU10350MO
NetShelter Rack PDU Advanced, Metered Outlet, 3PH, 22.1kW 400V 32A or 17.3kW 415V 30A
APDU10350MO 屬APC伺服器機櫃及機房設備產品。傑成系統有限公司(香港防盜)為APC產品安裝商及經銷商,可提供供應、安裝、調試、保養及維修,可配合網絡佈線、UPS 及機房環境監測一併規劃。方案可參考Server Room 架設及維修。規格以原廠資料為準。
產品說明
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs,
規格
主要規格
| Product or component type | PDU |
|---|---|
| Main Input Voltage | 415 V 3 phases; 400 V 3 phases |
| Input current limits | 30 A |
| Network frequency | 50/60 Hz |
| Main Output Voltage | 240 V |
| Input Connection Type | IEC 60309 30 A 3P + N + PE |
| Number of power socket outlets | 24 C13/C15/C19/C21 ; 24C13/C15 |
| Load capacity | 17300 VA |
| [In] rated current | 24 A |
| permissible voltage | 200…240 V; 346…415 V |
| Max current draw | 24 A |
| PDU type | Metered outlet |
| Protection type | Circuit breaker |
| Number of rack unit | 0U |
| Cable length | 1.8 m |
補充規格
| Mounting location | Side |
|---|---|
| Mounting mode | Rack-mounted |
| Mounting position | Vertical |
| Communication port protocol | 1000BASE-T; 10/100BASE-T |
| Height | 1780 mm |
| Width | 56 mm |
| Depth | 75 mm |
| Net weight | 9.6 kg |






