傑成系統有限公司 KNS SYSTEM LTD 保安公司牌照 1507 註冊電業承辦商 029394
香港防盜 SECURITY HK

APC APDU11250SW NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase

查詢價錢

NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase。規格以原廠資料為準。

此型號可由傑成系統有限公司上門安裝(保安牌照 1507)。身份為安裝商及經銷商。安裝見閉路電視安裝;保養見保養;其他公司系統維修見維修。

  • 持牌安裝(保安公司牌照 1507)
  • 原廠行貨,原廠保用
  • 全港免費上門勘察
貨號: APDU11250SW 分類: ,

描述

APDU11250SW

NetShelter Rack PDU Advanced Gen 2, Switched, 11.5kW, 3Phase

APDU11250SW 屬APC伺服器機櫃及機房設備產品。傑成系統有限公司(香港防盜)為APC產品安裝商及經銷商,可提供供應、安裝、調試、保養及維修,可配合網絡佈線、UPS 及機房環境監測一併規劃。方案可參考Server Room 架設及維修。規格以原廠資料為準。

產品說明

APC NetShelter Rack PDU Advanced (11K Series) provides reliable power distribution to IT equipment within server and/or networking racks. Switched outlets allow for turning outlets on or off remotely. PDU level power metering provides power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 in. (5.6 cm) wide form factor allows for more equipment in the rack. Outlets on the PDUs are color coded and labeled by breaker. Live Swap the NMC3 to minimize downtime in the unlikely event of an NMC power event. The rack PDU integrates with EcoStruxure IT through an NMC3 and can be accessed and configured via web, SNMP, and command line interface (CLI). A 10-foot (3-meter) input cord makes it easier for the PDU to reach the power supply. Rated to operate up to 60 C (140 F) at full load ensures reliability and availability even in today's high-density deployments. One gigabit Ethernet/network port (10/100/1000) enhances and standardizes network connectivity. Two link ports are available to cascade to up to 32 PDUs, with a network port sharing (NPS) feature to enable power sharing between Rack PDUs in the cascading group. Track or bill power usage confidently with 1% metering accuracy. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across mul

規格

主要規格

Product or component type PDU
Main Input Voltage 415 V 3 phases; 400 V 3 phases
Input current limits 20 A
Network frequency 50/60 Hz
Main Output Voltage 240 V
Input Connection Type IEC 60309 20 A 3P + N + PE
Number of power socket outlets 21 C13/C15/C19/C21 ; 21C13/C15
Load capacity 11500 VA
[In] rated current 16 A
permissible voltage 200…240 V; 346…415 V
Max current draw 16 A
PDU type Switched
Number of rack unit 0U
Cable length 3 m

補充規格

Mounting location Side
Mounting mode Rack-mounted
Mounting position Vertical
Communication port protocol 1000BASE-T; 10/100BASE-T
Colour Black
Height 1490 mm
Width 56 mm
Depth 75 mm
Net weight 7.2 kg